Carriere fb600e trip unit manual
Carriere fb600e trip unit manual






carriere fb600e trip unit manual

Upon completion of reassembly, the now completely remanufactured circuit breaker is retested andĬertified by a quality control engineer. Electrical devices and wiring harness are re-installed on the breaker and checked per factory or customer's wiring specifications.

carriere fb600e trip unit manual

New retainer pins or clips are carefully installed and checked.Current-carrying parts are reassembled and torqued to the manufacturer's or NETA standards.Contact assemblies are adjusted to the manufacture's guidelines.Frame parts are reassembled and aligned.

carriere fb600e trip unit manual

To the original factory specification as follows: RESA Power follows a meticulous qualityĬontrol procedure during reassembly to ensure years of trouble-free operation. Replaced, it’s time to put it all back together.

carriere fb600e trip unit manual

Now that the circuit breaker has been torn down with all of its components cleaned, refurbished or Voltage and amperage ratings will always meet or exceed original specifications.

  • Toggle switches, motor cut-off switches and relays are cleaned or replaced with identical or equivalent devices.
  • Control wiring is cleaned or replaced as necessary.
  • All springs are either replated or replaced.
  • (Nylon sleeve bearings do not require lubrication).
  • Roller and needle bearings are lubricated.
  • All standard hardware is replaced with new hardware.
  • Frame parts and mechanism parts are aluminum oxide blasted and then repainted or replated.
  • Insulated parts and pole pieces are solvent cleaned to be free of silicone, oil, paint and moisture.
  • Plated parts showing signs of peeling are replated or replaced.
  • Conductive parts are bead blasted as needed and cleaned using a vibratory cleaner.
  • Disassembly, Cleaning, and ReplacementĪll of our remanufactured circuit breakers are dismantled down to the last moving part: Noted items will be replaced later using equivalent or superior components. We’ll also note any springs showing signs of distortion, rust, brittleness, or (See “Testing Procedures” below for further description.)ĭuring our initial testing, we’ll take note of any wiring, taping, or heat shrinking that shows any Other tests to determine our starting point. We’ll then perform a “Ductor” test, a “Megger” test, and several We’ll start with an initial inspection and test of this Air Breaker. LA50A for you: Inspection and Initial Testing Remanufactured circuit breakers conform to NETA and ANSI C37 specifications, and all tolerances areĬhecked to meet or exceed the original manufacturer’s specifications. At RESA Power, we don’t just rebuild Air Breakers, we remanufacture them.








    Carriere fb600e trip unit manual